UNDERSTANDING THE DIFFERENCE BETWEEN A BREAK ROOM AND A KITCHEN

July 1, 2018 Clint Ryan
ADA Accessible Break Room Kitchen

Ever wonder what the difference is between a break room and a kitchen? There have been 3 technical memorandums issued from TDLR trying to resolve this question. The first, TM 2012-09 Employee Break Rooms, explains the difference between a break room and a kitchen. Memos, TM 2013-22 and 2013-23, provide clarifications to the storage requirements for each.

According to TDLR, the difference between a break room and a kitchen can be determined by answering one simple question: does the space contain cooking facilities that are built-in or fixed? Cooking facilities, defined as cooktops, ranges, ovens, convection ovens or microwaves, are considered built-in or fixed if they are attached to a cabinet, shelf or wall; connected to plumbing or gas; or hardwired to electricity. 

Why is it important to differentiate? Each type of room has its own requirements with regards to approach to the sink and storage. Establishing whether a room is a break room or kitchen will help you determine whether a parallel approach to a sink is permitted and what type and how much storage space must be compliant. There are some other differences, as well, which we will outline and discuss below.


BREAK ROOM

No fixed or built-in cooking facilities

Sink

  • A break room is required to have a forward approach to a sink. Refer to Figure G. (606.2 Clear Floor Space)

  • Clear floor space and knee and toe clearance under the sink is required. Refer to Figure H. (606.2 Clear Floor Space)

  • Sinks must be installed with the front of the higher of the rim or counter surface 34" max above the finish floor or ground. Refer to Figure J. (606.3 Height)

ADA Accessible Break Room Sink Forward Approach

Figure G - Break Room Sink Forward Approach

ADA Accessible Break Room Sink Knee & Toe Clearance

Figure H - Break Room Sink Knee & Toe Clearance

ADA Accessible Break Room Sink Height

Figure J - Sink Height

Storage Elements

  • For storage elements, at least one of each type must be within the standard reach ranges. (225.2 Storage)

  • Type refers to the design of the element (i.e. closets, cabinets, shelves , clothes rods, hooks and drawers) as well as the intended use (i.e. coat closets and supply closets). (Advisory 225.2 Storage and Technical Memorandum 2013-23)

  • In order to comply with TAS 225.2, base and wall cabinets shall be considered the same type if designed the same (i.e. both have doors), used for the same purpose and located in the same room. Refer to Figure K . (Technical Memorandum 2013-23)

ADA Accessible Break Room Storage One of Each Type

Figure K - Break Room Storage One of Each Type

Appliances

  • Appliances are not required to comply.

  • Microwaves are permitted to be placed on an open shelf out of reach range, but there must be another open shelf within reach range that could be used for the same purpose.


KITCHEN

Fixed or built-in cooking facilities

Sink

  • A kitchen is permitted to have a parallel approach to a sink, unless a cook top or range is provided. A parallel approach to a wet bar is always permitted. Refer to Figure L.

ADA Accessible Kitchen Parallel Approach

Figure L - Kitchen Parallel Approach

Storage Elements

  • For the storage elements, at least 50% of shelf spaces shall comply with reach ranges. This can be derived by calculating the linear distance of all shelf spaces and drawers and dividing that total in half. Refer to Figure M.

ADA Accessible Kitchen 50% Shelf Space in Reach Range

Figure M - 50% Shelf Space in Reach Range

Appliances

  • Appliances must comply with the requirements of 804.6 Appliances.

  • Clear floor space must be provided at each kitchen appliance. (804.6.1 Clear Floor or Ground Space)

  • All appliance controls must comply with operable parts and be within reach ranges. (804.6.2 Operable Parts)

  • There are additional requirements for appliances, which will not be discussed here. For full details, refer to 804.6 Appliances.

In Special Rooms Tags Accessible, Appliances, Break Room, Built-In, Clear Floor Space, Cooking Facilities, Forward Reach, Fixed, Kitchen, Knee and Toe Clearance, Obstructions, Operable Parts, Power Receptacles, Reach Ranges, Side Reach, Sinks, Storage
← REQUIREMENTS FOR ACCESSIBLE BENCHES AND WHICH ROOMS THEY ARE REQUIRED

ACCESS IS EVERYWHERE

ADA requires that toilet seat cover dispensers in restrooms comply.  This is a great location for it.  It complies with reach range and grab bar clearance (308.1 Reach Range and 609.3 Spacing).⁠
-⁠
-⁠
-⁠
#accessiseverywhere #accessibility #ada #archi
ADA guidelines require that grab bars have a minimum clearance of 12" above it for projecting objects.  Also, reach range requires a maximum height of 48" above the floor.  The height of the rear grab bar has a range of 33"-36". I
Side wall grab bars must have a length of 42" min (604.5.1 Side Wall)⁠
-⁠
-⁠
-⁠
#accessiseverywhere #accessibility #ada #architect #architecture #construction #interiordesign #interiorarchitecture #registeredaccessibilityspecialist #registeredac
Side wall grab bars must be horizontal (609.4 Position of Grab Bars)⁠
-⁠
-⁠
-⁠
#accessiseverywhere #accessibility #ada #architect #architecture #construction #interiordesign #interiorarchitecture #registeredaccessibilityspecialist #registeredaccessib
ADA urinal requirements (213.3.3 Urinals and 605 Urinals)⁠
-⁠
-⁠
-⁠
#accessiseverywhere #accessibility #ada #architect #architecture #construction #interiordesign #interiorarchitecture #registeredaccessibilityspecialist #registeredaccessibilityspecia
ADA requires that mirrors located above lavatories be installed 40" maximum to the bottom of the reflecting surface.  If there is a full length mirror located in the toilet room, then the mirror above the lavatory is not required to comply. Here
FOLLOW

Clint Ryan, RAS 1333
972-822-0554 | clint.ryan@rethinkaccess.com


Copyright © 2025 - reThink Access
All Rights Reserved

Privacy Policy | Terms and Conditions